Tempeff
Showing all 4 results
-
Air Handling Units, Heat Recovery Systems, Ventilation
Tempeff RG Series
Dual Core High Efficiency Heat Recovery Unit
750 to 96 000 CFM
Recovery efficiency rate upto to 90% in winter and 80% in summer (+-5%)
Construction in galvanized steel G90 with foam injected insulation
Cooling and heating coils available for water, refrigerant and steam
Indoor and outdoor construction
Recirculation and free cooling
Internal shut off dampers
No requirements for defrost strategy
Switchover damper section comprised of multi section low leakage dampers (4) with actuators
Electric actuators by default, pneumatic on sizes RG 33000 and largerSKU: n/a -
Air Handling Units, Heat Recovery Systems, Ventilation
Tempeff RGN Dedicated Path Series
Dual Core High Efficiency Heat Recovery Unit
2000 to 42 000 CFM
Indoor units with exhaust and supply air ducts on the same end
Unique design keeping outside air intake and exhaust air seperate
Recovery efficiency rate upto to 90% in winter and 80% in summer (+-5%)
Construction in galvanized steel G90 with foam injected insulation
Cooling and heating coils available for water, refrigerant and steam
Recirculation and free cooling
Internal shut off dampers
No requirements for defrost strategy
Switchover damper section comprised of low leakage dampers with electric actuatorsSKU: n/a -
Air Handling Units, Heat Recovery Systems, Ventilation
Tempeff RGN Series
Dual Core High Efficiency Heat Recovery Unit
2000 to 42 000 CFM
Indoor units with exhaust and supply air ducts on the same end
Recovery efficiency rate upto to 90% in winter and 80% in summer (+-5%)
Construction in galvanized steel G90 with foam injected insulation
Cooling and heating coils available for water, refrigerant and steam
Recirculation and free cooling
Internal shut off dampers
No requirements for defrost strategy
Switchover damper section comprised of low leakage dampers with electric actuatorsSKU: n/a -
Air Handling Units, Heat Recovery Systems, Ventilation
Tempeff RGSP Series
Dual Core High Efficiency Heat Recovery Unit
110 to 2000 CFM
Indoor units for smaller capacity
Recovery efficiency rate upto to 90% in winter and 80% in summer (+-5%)
Construction in galvanized steel G90 with foam injected insulation
Cooling and heating coils available for water, refrigerant and steam
Recirculation and free cooling
Internal shut off dampers
No requirements for defrost strategy
Switchover damper section comprised of low leakage dampers with electric actuatorsSKU: n/a