SPX
Showing 1–15 of 18 results
-
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley Aquatower
8 to 126 tons per cell
Induced flow and crossflow
CTI Certified
Galvanised steel, stainless steel or fiberglass construction
Integral louvers for zero water splashout and superior Winter operation
Available with a one year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley AV
125 to 772 tons per cell
Induced flow and crossflow
CTI Certified
Galvanised steel or stainless steel construction
Integral louvers for zero water splashout and superior Winter operation
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers and Heat Rejection, Evaporative Fluid Cooler (Closed System)
SPX Marley DT
45 to 265 tons per cell
Induced flow and counter flow
CTI Certified
Low sound fans standard on all models
Galvanised steel construction with stainless steel component options
HDG steel or stainless steel coil material
Triple pass inlet louvers and drift eliminators to conserve water
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers and Heat Rejection, Evaporative Fluid Cooler (Closed System)
SPX Marley LW
18 to 107 tons per cell
Induced flow and counter flow
CTI Certified
Quiet ECM fans with integral VSD on all models
Copper coil standard
Low-clog spray system
Triple pass drift eliminators
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers and Heat Rejection, Evaporative Fluid Cooler (Closed System)
SPX Marley MC
Forced draft counterflow fluid cooler
Galvanized steel with optional stainless steel construction
Reliable and performant for high-end applications with low noise and space saving footprint
Suitable for all critical indoor and outdoor applications
Combines the function of a cooling tower and heat exchanger into one system
Electric basin heaters
Fluid cooler coil may carry glycol solutions to protect against freezing or hold an increased flowrate
Indoor storage tank
Combination of PVC piping and polypropylene nozzles which are very resistant to build-upsSKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley MCW
18 to 600 tons per cell
Forced flow and counter flow
CTI Certified
Galvanised steel or stainless steel construction
Easy removal of fill (heat transfer media)
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley MD
89 to 756 tons per cell
Induced flow and counter flow
CTI Certified
Galvanised steel or stainless steel construction
Triple pass inlet louvers and drift eliminators to conserve water and improve winter operation
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers and Heat Rejection, Evaporative Fluid Cooler (Closed System)
SPX Marley MH
31 to 628 tons per cell
Induced flow and counter flow
CTI Certified
Copper coil standard
Galvanized steel or stainless steel construction
Factory assembled, modular contruction
Singleflow or doubleflow models
Compatible with numerous process fluids (water, water/glycol, oil, etc.)
Optional dry coil for part load dry operation
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley NC
101 to 1455 tons per cell
Induced flow and crossflow
CTI Certified
Low sound fans standard on all models
Galvanised steel or stainless steel construction
Integral louvers standard for maximum water containment and superior Winter operation
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley NC Everest
1311 to 2189 tons per cell
Induced flow and crossflow
CTI Certified
Low sound fans standard on all models
Single or dual inlet piping
Galvanised steel or stainless steel construction
Integral louvers standard for maximum water containment and superior Winter operation
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley NX Fiberglass
121 to 372 tons per cell
Induced flow and crossflow
CTI Certified
Non-corrosive fiberglass construction
Certified low sound fans standard on all models
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley QuadraFlow Field Assembled
Cooling, Cooling Towers (Open System), Cooling Towers and Heat RejectionSPX Marley QuadraFlow Field Assembled
129 to 1047 tons per cell
Induced flow and crossflow
CTI Certified
Low sound fans standard on all models
Galvanised steel or stainless steel construction
Integral louvers standard for maximum water containment and superior Winter operation
Factory fabricated and assembled at the jobsite
Available with a five year mechanical warrantySKU: n/a -
Cooling, Cooling Towers (Open System), Cooling Towers and Heat Rejection
SPX Marley Sigma Field Assembled
Cooling, Cooling Towers (Open System), Cooling Towers and Heat RejectionSPX Marley Sigma Field Assembled
380 to 10100 gpm
Field erected
Induced flow and crossflow
Stainless steel, fiberglass or wood construction
Integral louvers standard for maximum water containment and superior Winter operation
Available with a five year mechanical warranty for most applicationsSKU: n/a -
-