Raypak
Showing all 13 results
-
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak EconoPak Series Water Heaters
90 MBTH to 399 MBTH
Indoor and outdoor models
82% thermal efficiency
Factory mounted and wired stainless steel pump
Consistent 140°F water delivery, even during peak demand times
Compact
20 year limited warranty
SKU: n/a -
Heating, Hydronic Boilers, Non-Condensing Boilers
Raypak Hi Delta Series Boilers
100 MBTH to 2,340 MBTH
Indoor and outdoor models
84% efficiency
Cat I (vertical venting)/Cat III (sidewall venting)
Cast iron (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
Ducted combustion air ready
105°F minimum inlet water temperature
2 to 4 stage operation
Cascade control of up to 4 units
VERSA IC® Control Package with LCD Display
Diagnostics Center with History, English, no codes
0-10 VDC BMS Interface
Optionnal Dual FuelSKU: n/a -
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak Hi Delta Series Water Heaters
100 MBTH to 2,340 MBTH
Indoor and outdoor models
84% efficiency
Cat I (vertical venting)/Cat III (sidewall venting)
Cast iron (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
Ducted combustion air ready
105°F minimum inlet water temperature
On/Off to 4 stage operation
Cascade control of up to 4 units
VERSA IC® Control Package with LCD Display
Diagnostics Center with History, English, no codes
0-10 VDC BMS Interface
Optionnal Dual Fuel
SKU: n/a -
Heating, Hydronic Boilers, Non-Condensing Boilers
Raypak Hi-Delta SS Residential Series Boilers
100 MBTH to 299 MBTH
Indoor and outdoor models
85% AFUE
Cat I (vertical venting)/Cat III (sidewall venting)
Cast iron (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
Ducted combustion air ready
105°F minimum inlet water temperature
2 stage operation
Electronic controller with outdoor reset
Stainless steel pump with flanges included
SKU: n/a -
Heating, Hydronic Boilers, Non-Condensing Boilers
Raypak Modulating Vertical Series Boilers
100 MBTH to 4,000 MBTH
Indoor and outdoor models
84% thermal efficiency at full rate
Cat I/IV venting required (depending on the model)
Cast iron/Bronze (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
120°F minimum inlet water temperature
235°F maximum operable outlet water temperature
Electronic modulation up to 7:1 turndown
Cascade control of up to 4 units
VERSA IC® Control Package with Built-In Outdoor Reset Function, LCD Display
Diagnostics Center with History, English, no codes
0-10 VDC BMS Interface
Small footprint
SKU: n/a -
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak Modulating Vertical Series Water Heaters
500 MBTH to 4,000 MBTH
Indoor and outdoor models
84% thermal efficiency at full rate
Cat I/IV venting required (depending on the model)
Cast iron/Bronze (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
120°F minimum inlet water temperature
150°F maximum setpoint temperature
Electronic modulation up to 7:1 turndown
Cascade control of up to 4 units
VERSA IC® Control Package with Built-In Outdoor Reset Function, LCD Display
Diagnostics Center with History, English, no codes
0-10 VDC BMS Interface
Small footprint
SKU: n/a -
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak Raytherm Series Water Heaters
181 MBTH to 4,000 MBTH
Indoor or outdoor models
82% thermal efficiency
Cat I venting
Cast iron/Rugged All-Brass (Brass opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
24-Volt Controls
Floating return header
Corrosion resistant steel
Stainless steel burners
Optionnal Low Nox Water Heater
Mechanical modulation, On/Off, 2-Stage, 4-Stage operation (depending on the model)
A condensing version is available
SKU: n/a -
Heating, Hydronic Boilers, Non-Condensing Boilers
Raypak Raytherme Series Boilers
181 MBTH to 4,000 MBTH
Indoor or/& outdoor models
80% to 82% thermal efficiency
Cat I venting
Rugged All-Brass (Glass-lined/Cast-iron opt.) headers with copper (cupronickel opt.) finned tube heat exchanger
24-Volt Controls
Floating return header
Corrosion resistant steel
Stainless steel burners
Optionnal Low Nox Boiler
Mechanical modulation, On/Off, 2-Stage, 4-Stage operation (depending on the model)SKU: n/a -
Condensing Boilers, Heating, Hydronic Boilers
Raypak X-Therm Series Boilers
999 MBTH to 4,000 MBTH
Indoor and outdoor models
96% efficiency at full fire
Condensing, Cat IV venting required
Cast iron (Brass opt.) headers and pumps with copper (cupronickel opt.) finned tube heat exchanger
50°F minimum continuous inlet temperature
Modulation up to 12.5:1 turndown
On-board diagnostic center, real English, no codes
Primary-secondary piping required
VERSA IC® control package
Built-in cascade function for up to 4 boilersSKU: n/a -
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak X-Therm Series Ultra-High Efficiency Water Heaters
Heating, Non-Condensing Water Heaters, Water HeatersRaypak X-Therm Series Ultra-High Efficiency Water Heaters
999 MBTH to 4,000 MBTH
Indoor and outdoor models
97% efficiency at full fire
Condensing, Cat IV venting required
Brass headers and pumps with copper (cupronickel opt.) finned tube heat exchanger
50°F minimum continuous inlet temperature
Modulation up to 12.5:1 turndown
On-board diagnostic center, real English, no codes
Primary-secondary piping required
VERSA IC® control package
Built-in cascade function for up to 4 boilers
Low NOxSKU: n/a -
Heating, Hydronic Boilers, Non-Condensing Boilers
Raypak Xfyre Series Boilers
300 MBTH to 850 MBTH
Indoor and outdoor models
94% efficiency condensing (up to 99% at part load)
Cat IV venting required
Small footprint
Top side water connections – allows side by side installation
316L welded stainless steel heat exchanger and copper plumbing
Modulation up to 5:1 turndown
50°F Minimum inlet water temperature
On-board diagnostic center, English, no codes
Built-in cascade function for up to 4 boilers
VERSA IC® control package
SKU: n/a -
Heating, Non-Condensing Water Heaters, Water Heaters
Raypak Xfyre Series Water Heaters
300 MBTH to 850 MBTH
Indoor and outdoor models
95% efficiency condensing (up to 99% at part load)
Cat IV venting required
Small footprint
Top side water connections – allows side by side installation
316L welded stainless steel heat exchanger and copper plumbing
Modulation up to 5:1 turndown
50°F Minimum inlet water temperature
On-board diagnostic center, English, no codes
Built-in cascade function for up to 4 boilers
VERSA IC® control packageSKU: n/a -
Condensing Boilers, Heating, Hydronic Boilers
Raypak Xpak Series Residential Wall Hung Boilers
87 MBTH to 120 MBTH
Indoor installation only
Bottom water connections – allows side by side installation
Built-in 3-speed non-ferrous pump
Modulation up to 4:1 turndown
Whisper-quiet operation
Built-in outdoor reset control logic
Cabinet completely encloses all controls and wiringSKU: n/a